Skip Menu |
 

This queue is for tickets about the Protocol-Modbus CPAN distribution.

Report information
The Basics
Id: 96275
Status: new
Priority: 0/
Queue: Protocol-Modbus

People
Owner: Nobody in particular
Requestors: alexandre.bustico [...] free.fr
Cc:
AdminCc:

Bug Information
Severity: (no value)
Broken in: (no value)
Fixed in: (no value)



Subject: proposed fix and add read input register
Date: Fri, 6 Jun 2014 10:50:02 +0200
To: bug-Protocol-Modbus [...] rt.cpan.org
From: alexandre bustico <alexandre.bustico [...] free.fr>
Download (untitled) / with headers
text/plain 415b
Hello, and thanks for your module that i have been able to use after applying few small patches over 0.10 version. ° fix : suppress the select (undef,undef,undef,0.25) which was slowing communication without seen benefits. ° implement FUNC_READ_INPUT_REGISTERS function Attached is a recursive patch that i have made to successfully communicate with a robotic arm modbus device. have a good day Alexandre

Message body is not shown because sender requested not to inline it.