Skip Menu |
 

This queue is for tickets about the SNMP-Info CPAN distribution.

Report information
The Basics
Id: 106254
Status: resolved
Priority: 0/
Queue: SNMP-Info

People
Owner: EMILLER [...] cpan.org
Requestors: d.sieborger [...] ru.ac.za
Cc:
AdminCc:

Bug Information
Severity: (no value)
Broken in: (no value)
Fixed in: (no value)



Subject: Add new sysObjectID mapping for Ubiquiti
Date: Wed, 05 Aug 2015 10:16:35 +0200
To: bug-SNMP-Info [...] rt.cpan.org
From: David Siebörger <d.sieborger [...] ru.ac.za>
Download (untitled) / with headers
text/plain 642b
Some new versions of firmware for Ubiquiti devices (AirOS 5.6.x) have introduced a new Ubiquiti SNMP MIB and changed the sysObjectID value. The attached patch restores correct detection of our Ubiquiti devices. $ snmpget -v1 -cXXX HOSTNAME sysObjectID.0 RFC1213-MIB::sysObjectID.0 = OID: UBNT-AirMAX-MIB::ubntAirMAX $ snmpget -On -v1 -cXXX HOSTNAME sysObjectID.0 .1.3.6.1.2.1.1.2.0 = OID: .1.3.6.1.4.1.41112.1.4 The MIB is available from here: https://community.ubnt.com/t5/airMAX-Frequently-Asked/airMAX-Where-can-I-find-the-latest-MIB-for-airOS/ta-p/1294379 -- David Siebörger Information & Technology Services, Rhodes University
Download ubnt.patch
text/x-diff 349b

Message body is not shown because sender requested not to inline it.

Thanks for the patch, it has been committed and should be included version 3.30.